Import Guide for Amplifiers (Audio Amplifiers)
Automatically translated from Korean.
In brief — 220V household amplifiers are subject to KC supplier’s declaration of conformity, and stereo amplifiers must also have their standby power consumption reported. HS 8518.40-0000 has a 0% WTO bound tariff rate, so no customs duty applies.
Products covered in this guide — Amplifiers (household audio amplifiers)
From other guides — Import Guide for Digital Pianos and Electronic Keyboards · Import Guide for Action Cameras · Import Guide for Portable Photo Printers
What to check first
Is it an amplifier only, or an audio amplification set? — The tariff schedule lists “audio-frequency electric amplifiers” and “electric sound amplifier sets” separately.
Is it directly connected to 220V, or does it use an AC adapter? — The amplifier subheading does not include a note that separately covers low-voltage products.
Does it have wireless transmission and reception functions, such as Bluetooth? — Check with the National Radio Research Agency or a testing laboratory whether it is subject to conformity assessment for wireless devices.
Order of tasks
Obtain the power supply details (220V or adapter), whether it is stereo, Bluetooth functionality, and set configuration from the factory → What to check first
If it is standalone, classify it under 8518.40-0000; if it is an audio amplification set, classify it under 8518.50-0000 → HS code
For a 220V main unit, check KC supplier’s declaration of conformity; for the adapter, check safety certification → Certification and requirements
Measure and report the standby power consumption of a stereo amplifier before sale → Certification and requirements
Complete electromagnetic-wave conformity registration, and if it has wireless functionality, check whether it is subject to conformity assessment for wireless devices before applying the required markings → Certification and requirements
Prepare the documents subject to customs clearance verification and file the import declaration — the 0% WTO bound tariff rate is lower than the basic tariff rate and is applied first → Certification and requirements · Taxes
HS code
For products like these | Classification number (description) | Basic tariff rate |
|---|---|---|
Amplifier — standalone audio amplifier | 8518.40-0000 (audio-frequency electric amplifiers) | 8% |
Amplifier set — audio amplification set | 8518.50-0000 (electric sound amplifier sets) | 8% |
If the set configuration is unclear, determine the classification through an advance ruling on tariff classification.
The classification numbers in this guide are representative examples for explanatory purposes and do not constitute a definitive classification. The Korea Customs Service and testing or certification authorities make the final determination on classification and whether certification or other requirements apply.
Certification and requirements
Must obtain — The importer applies
Task | When | Differences by power supply |
|---|---|---|
220V main unit — KC supplier’s declaration of conformity (amplifier) | Before import | Excluded if the main unit is an adapter type rated at 42V DC or less (there is no low-voltage note for this subheading) |
Standby power measurement and reporting (audio equipment such as stereo amplifiers) | Before sale, within 60 days after measurement | Household and office audio equipment rated at 1,000W or less (check with the Korea Energy Agency whether it is excluded) |
Electromagnetic-wave conformity registration | Before import | If powered by USB or batteries, self-confirmation of conformity applies |
Check whether it is subject to conformity assessment for wireless devices | Before import | When it has wireless transmission and reception functions, such as Bluetooth |
Country-of-origin marking on the product and packaging | At the time of import | Same for all power supplies |
What customs checks — Customs checks these during clearance
Classification number | Electrical product verification | Radio-wave verification |
|---|---|---|
8518.40-0000 | Supplier’s declaration of conformity | Conformity assessment |
8518.50-0000 | Supplier’s declaration of conformity | Conformity assessment |
Depending on the case — The importer handles these separately when applicable
If an adapter is included — The adapter must separately obtain safety certification as a DC power supply.
Taxes
This is an example of importing goods with a dutiable value of KRW 8 million from the countries of origin for each classification number.

Declared number and tariff rate | Customs duty | Value-added tax (10% of dutiable value + customs duty) |
|---|---|---|
8518.40 Mexico · No certificate of origin (WTO bound rate) 0% | KRW 0 | KRW 800,000 |
8518.50 China · No certificate of origin (WTO bound rate) 0% | KRW 0 | KRW 800,000 |
The amounts in this example are hypothetical values for explanatory purposes.
For both classification numbers, the 0% WTO bound tariff rate (the maximum rate committed under WTO agreements) is lower than the basic tariff rate and is applied first (Types of tariff rates and order of application).
8518.40-0000 Audio-frequency electric amplifiers — Basic tariff rate 8% · WTO bound tariff rate 0%
The following are examples of the tariff rates applicable by country of origin for this classification number. Check with a customs broker for other countries of origin.
Country of origin | Applicable tariff rate | Basis of agreement |
|---|---|---|
Mexico · China · Switzerland · Germany · Japan · United States · Vietnam · Indonesia · Romania · Czech Republic | 0% | WTO bound tariff rate |
8518.50-0000 Electric sound amplifier sets — Basic tariff rate 8% · WTO bound tariff rate 0%
The following are examples of the tariff rates applicable by country of origin for this classification number. Check with a customs broker for other countries of origin.
Country of origin | Applicable tariff rate | Basis of agreement |
|---|---|---|
China · United States · Italy · Spain · Japan · Canada · Greece · Germany · Vietnam · Denmark | 0% | WTO bound tariff rate |
Shipping and customs clearance tips
Complete standby power measurement before the goods arrive — The report must be completed before sale.
Obtain the main unit’s input voltage and the adapter model name separately in the specifications — The lists of products subject to KC requirements differ for the main unit and the adapter.
Agree with the factory on individual packaging and loading direction for tube amplifiers — Glass components are vulnerable to impact.
Common mistakes
Misconception: “There are no energy requirements if I obtain KC certification.” — Incorrect. Stereo amplifiers are included among audio equipment subject to standby power measurement and reporting.
Misconception: “KC certification for the main unit also covers the adapter.” — Incorrect. The adapter must separately obtain safety certification as a DC power supply.
Misconception: “Apply the 1.6% preferential tariff rate with a certificate of origin.” — Incorrect. The 0% bound tariff rate is lower and is applied first.